Quick Answer
Calculate EDI Stack Boron Leakage Concentration Predictor
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
EDI Stack Boron Leakage Concentration Predictor calculator computes Boron Breakthrough Concentration in mol/m^3 using the defined engineering formula and the input values provided. Boron Breakthrough Concentration is expressed in mol/m^3. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- Feed Water pH = 7
- Stack Current Density = 100
- Inlet Boron Concentration = 1.0E-6
- pH Sensitivity Coefficient = 1.8
- Current Density Decay Coefficient = 0.45
- Reference Current Density = 100
Expected Result:
- Boron Breakthrough Concentration = 6.0653065971263E-7
Engineering Interpretation:
Under the given input conditions, the calculated result is: Boron Breakthrough Concentration = 6.0653065971263E-7 mol/m^3.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
boron breakthrough concentration = inlet boron concentration * pow(10.0, -ph sensitivity coefficient * (feed water ph - 7.0)) * exp(-current density decay coefficient * stack current density / reference current density)Formula family: formula_ultrapurewater_edi_stack_boron_leakage_vs_ph_current_density_predictor
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| pH | Feed Water pH | INPUT | Feed Water pH |
| current_density | Stack Current Density | INPUT | Stack Current Density |
| C_b0 | Inlet Boron Concentration | INPUT | Inlet Boron Concentration |
| k_pH | pH Sensitivity Coefficient | INPUT | pH Sensitivity Coefficient |
| k_j | Current Density Decay Coefficient | INPUT | Current Density Decay Coefficient |
| j_ref | Reference Current Density | INPUT | Reference Current Density |
| boron_breakthrough_concentration | Boron Breakthrough Concentration | OUTPUT | Boron Breakthrough Concentration |
Calculation Steps
- Enter the feed water ph in dimensionless.
- Enter the stack current density in A/m^2.
- Enter the inlet boron concentration in mol/m^3.
- Enter the ph sensitivity coefficient in dimensionless.
- Enter the current density decay coefficient in dimensionless.
- Enter the reference current density in A/m^2.
- Step 1: Compute boron breakthrough concentration.
- Read the boron breakthrough concentration (mol/m^3) from the results.
Engineering Summary
Calculate EDI Stack Boron Leakage Concentration Predictor
Frequently Asked Questions
What does this calculator calculate?
The EDI Stack Boron Leakage Concentration Predictor calculator estimates Boron Breakthrough Concentration based on the input parameters you provide
Why is feed water ph important in this calculation?
feed water ph is used directly in the calculation of boron breakthrough concentration. Its effect on the result depends on the complete formula and the values of the other inputs.. When you enter feed water ph in dimensionless, the calculator uses it in the engineering formula to compute the output
How should I interpret the result boron breakthrough concentration?
The calculator outputs boron breakthrough concentration in mol/m^3. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Feed Water pH (dimensionless), Stack Current Density (A/m^2), Inlet Boron Concentration (mol/m^3), pH Sensitivity Coefficient (dimensionless), Current Density Decay Coefficient (dimensionless), Reference Current Density (A/m^2). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
TOC load calculator
UV 185-nm TOC Destruct Efficiency Calculator for Ultrapure Water Systems Calculator
Ultrafiltration Sub-0.1 μm Particle Log Removal Value (LRV) Validation Formula Calculator
Ultrapure Water Chemical Dosing Loop Flow Rate Calculator
Ultrapure Water Chemical Dosing System Recirculation Velocity Calculator
Ultrapure Water Distribution Loop Biofilm Growth Risk Index Calculator
Browse More Tools